• We fit components with insulation blankets and shields every day to protect equipment and employees. Our highly professional staff know how to engineer and design insulation and safety solutions for harsh operating conditions found in locations including processing plants, marine vessels and oil platforms.
  • UL certified Intumescent fire resistant and fire retardant paint. Albi Clad 800 should be specified wherever long-lasting, exterior fireproofing is needed. ASTM E-119/ UL 263 and UL 1709 classified for up to 3 hours protection of interior and exterior steel.
  • PASSIVE FIRE PROTECTION SOLUTIONS AUSTRALIAN STANDARDS ... ́ UL 2079 ́ Certifire ́ EN 10140-2 ́ EN 15651-1, -4 ́ ISO 11600 F 25 LM ́ ASTM C 920 class 25 Packaging
  • This epoxy based intumescent coating provides a highly effective barrier to petrochemical and industrial fires, assuring the function and ability to control critical safety systems and shut down operations. Real world testing exceeds UL 1709, ASTM E1529/E119, NFPA 251, and API 607 specifications.
  • Figure 9 Diagram of UL Fire Resistance Directory Design No. G708. ¾ Fire Protection – As I briefly discussed earlier, open web steel joist systems are difficult to fireproof. The spray-applied fireproofing currently in use does not easily adhere to the narrow web members in these joists.
  • That means it satisfies UL’s 1709 Standard for Rapid Rise Fire Tests of Protection Materials for Structural Steel, the most common industry standard required by insurance providers. Albi Clad 800 is most commonly applied at a thickness of 350 mils to achieve a 1.5-hour fire rating, but it can be applied at a 750 mil thickness when a 3-hour ...
Advantages Proven fire resistance to UL1709 fire insult, durability. Application Carboline fire expert (ex-Navy) indicated that a 2-hour Instructions UL 1709 rating with 0.415" on steel. Primary Application Long-lasting fireproofing with high abrasion & impact.
Gypsum Wallboard Column Fireproofing(CAD FILE NAME GOLDN.DWG OR GOLDN.DXF) No. Fire Rating Ref. Design No. Description LIGHT COLUMN 1 1 hr. UL X528 Two layers of 1/2" (12.7 mm) Fire-Shield C Wallboard furred from TS 4x4x0.188 tube steel GA CM 1452 column by 1 5/8" (43.3 mm) steel stud each corner.
() Underwriters Laboratories Inc. - ANSI/UL 1709 XR625.www.boltcap.com Built Environment Oil & Gas Markets BS-476 (2 hrs) ASTM E-119 / UL 263 (3 hrs) UL 1709 (up to 4 hrs pool fire) ISO 22899 (2 hr jet fire)
Fire ratings of construction assemblies can also be found in the Underwriters Laboratory (or UL) Fire Resistance Directory, PCI Manual 124 ‐ 1, ACI 216.1, NCMA TEK 07 ‐ 01C, and the Gypsum Associations Fire ResistanceDesign Manual.
fourth in ASTM E119 or UL 263 or section 703.3(Alt. methods for fire resistance) – 703.3 states that the application of alt. methods must be based on acceptance criteria specified in ASTM E119 or UL 263 • Materials incorporated into the element or assembly must provide Fire ratings of construction assemblies can also be found in the Underwriters Laboratory (or UL) Fire Resistance Directory, PCI Manual 124 ‐ 1, ACI 216.1, NCMA TEK 07 ‐ 01C, and the Gypsum Associations Fire ResistanceDesign Manual.
passive fire protection SIPA is a leading manufacturer of passive fire protection systems. Our flexible covers are designed to insulate equipment and delay temperature rise in the event of a UL1709 rapid rise fire, while maintaining structural integrity at temperatures higher than 2000°F and follow requirement of API 2218. SAUDI ARAMCO TOTAL REFINING & PETROCHEMICAL COMPANY Fireproofing for Plants JERES-B-006 Fireproofing for Plants